Ultrasonic clamp-on flowmeter Proline Prosonic Flow P 500 – noninvasive and easy to install – no process interruption – maintenance-free operation up to 550 °C

- F
- L
- E
- X
Award-winning high-temperature clamp-on sensor: Prosonic Flow P 500 has won the
Specs at a glance
-
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F) -
Max. process pressure
N/A
Field of application
Prosonic Flow P 500 is the
Benefits
-
Flexible mounting – FlowDC reduces inlet runs to a minimum
-
High safety standards – Prosonic Flow P 500 is developed according to IEC 61508 functional safety requirements and holds international approvals for hazardous area, Zone 1 and Class I, Division 1
-
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals, also in high-temperature applications (≤550 °C/1022 °F)
-
User-friendly operation – the web server offers full remote access, while the device’s touch display offers convenient on-site interaction
-
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
-
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
Videos
-
How FlowDC function reduces inlet runs to a minimum
-
Straightforward application of FlowDC in practice
-
Reliable operation even at high temperatures
-
The ultrasonic flow measuring principle
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Ultrasonic flow
-
Product headline
Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os.
Constant accuracy even when mounted with short inlet run thanks to FlowDC.
Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals. -
Sensor features
High safety standards – SIL by design,
international hazardous area approvals. Long-term stable signal – maintenance-free
permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available.
Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +550 °C (–40 to +1022 °F). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety –
freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160")
-
Sensor materials
Clamp on system:
Sensor holder 1.4301/304, 1.4404/316L
Sensor housing 1.4301/304, 1.4404/316L
Strapping bands 1.4301/304, 1.4404/316L -
Measured variables
Volume flow, sound velocity, flow velocity, totalizer
-
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Max. process pressure
N/A
-
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F) -
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
–50 to +60 °C (–58 to +140 °F) optional -
Sensor housing material
N/A
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
-
Degree of protection
Sensor remote version: IP68 type 6P
Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control(operation from outside)
Optional: WLAN
Configuration via local display and operating tools possible -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, Modbus RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, FM/CSA, EAC, UK Ex, KC
-
Other approvals and certificates
Other approvals and certificates
-
Product safety
CE, C-tick, EAC-marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100
Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
-
-
Technical Information (TI)
TI Proline Prosonic Flow P 500
English version - 01/2024
New version available in English
Ultrasonic time-of-flight flowmeter
EN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
7.2 MB
File name:
TI01504DEN_0224-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Prosonic Flow P 500
English version - 01/2024
New version available in English
Ultrasonic time-of-flight flowmeter HART
EN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
9.7 MB
File name:
BA02025DEN_0224-00.pdf
-
-
-
Technical Information (TI)
TI Proline Prosonic Flow P 500
-
Technical Information (TI)
English version - 01/2024Ultrasonic time-of-flight flowmeter
EN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
7.2 MB
File name:
TI01504DEN_0224-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Prosonic Flow P 500
-
Operating Instruction (BA)
English version - 01/2024Ultrasonic time-of-flight flowmeter
HARTEN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
9.7 MB
File name:
BA02025DEN_0224-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Prosonic Flow P 500
-
Operating Instruction (BA)
English version - 01/2024Ultrasonic time-of-flight flowmeter
Modbus RS485EN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
8.9 MB
File name:
BA02026DEN_0224-00.pdf
-
-
-
Device Parameter (GP)
GP Proline Prosonic Flow P 500
-
Device Parameter (GP)
English version - 01/2024Ultrasonic time-of-flight flowmeter
HARTEN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
2.4 MB
File name:
GP01147DEN_0224-00.pdf
-
-
-
Device Parameter (GP)
GP Proline Prosonic Flow P 500
-
Device Parameter (GP)
English version - 01/2024Ultrasonic time-of-flight flowmeter
Modbus RS485EN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
2.9 MB
File name:
GP01148DEN_0224-00.pdf
-
-
-
Short Instruction (KA)
KA Flowmeter Proline Prosonic Flow P
-
Short Instruction (KA)
English version - 01/2024Ultrasonic time-of-flight sensor
EN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
1.8 MB
File name:
KA01474DEN_0224-00.pdf
-
-
-
Short Instruction (KA)
KA Proline 500
-
Short Instruction (KA)
English version - 01/2024Modbus RS485 transmitter
with ultrasonic time-of-flight sensorEN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
2.4 MB
File name:
KA01476DEN_0224-00.pdf
-
-
-
Short Instruction (KA)
KA Proline 500
-
Short Instruction (KA)
English version - 01/2024HART transmitter
with ultrasonic time-of-flight sensorEN 31/01/202410/05/2021Language:
English
Version:
31/01/2024
File size:
2.3 MB
File name:
KA01475DEN_0224-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter
-
Installation Instructions (EA)
English version - 08/2021Prosonic Flow 500
EN 01/08/2021Language:
English
Version:
01/08/2021
File size:
819.1 KB
File name:
EA01335DA2_0121.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the sensor, sensor holder, Installation set
-
Installation Instructions (EA)
English version - 03/2024Prosonic Flow P 500, I, W 400
EN 01/03/202415/12/202101/08/2021Language:
English
Version:
01/03/2024
File size:
1.4 MB
File name:
EA01368DA2_0323-00.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .