iTHERM ModuLine TM131

Product picture of modular RTD and TC thermometer ModuLine TM131 with dual seal ©Endress+Hauser

Thermometer with second process barrier, so-called 'dual seal'

Product picture of modular RTD and TC thermometer ModuLine TM131 heavy duty ©Endress+Hauser

Stainless steel version with XP proof terminal head

Product picture of modular RTD and TC thermometer ModuLine TM131 QuickNeck ©Endress+Hauser

QuickNeck version for fast disassembly of the insert

Trend-setting, high modular and robust thermometer for a wide range of industrial applications

RTD or TC assembly complete with manufactured thermowell or to be used with existing thermowell. An optional head transmitter, with all common communication protocols - Bluetooth® technology inclusive, and special features like iTHERM QuickNeck, for tool-free easy recalibration, vibration-resistant and fast-response sensor and thermowell technology (iTHERM StrongSens, QuickSens) as well as hazardous area approvals makes the device ready to use with enhanced measurement accuracy and reliability.

This product is not available in this market.

  • Benefits

    • Second process barrier with failure indication offering valuable health status information

    • iTHERM QuickSens: fastest response times 1.5 s for optimum process control

    • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety

    • ...

  • Field of application

    • Universal range of application

    • Measuring range: –200 to +1100 °C (–328 to +2012 °F)

    • Pressure range up to 100 bar (1450 psi)

    • Degree of protection: up to IP 68

    • Vibration-resistant sensor elements up to 60g

    • Improved ease of maintenance (sensor replacement...

Features and specifications

Back

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    modular temperature assembly

    universal range of application

    suitable for hazardous areas

    with neck or QuickNeck

    incl. thermowell / protection tube (metal) or to be installed into thermowell

    can be used with StrongSens, QuickSens insert

    for fast response times

  • Terminal head

    TA30A - comfort hinged cover E+H - Alu - low lid - with/without display

    TA20AB - small lid with screews - Alu

    TA30D - comfort high hinged cover E+H - Alu

    TA30EB - comfort screewed cover E+H - Alu - low lid - with/without display

    TA30R - low or high screewed cover - E+H - stainless steel - with/without display

    TA30H -explosion proof screewed cover - E+H - Alu or stainless steel - with/without display

    Dual-compartment fieldhousing - explosion proof - big backlit display - Alu or stainless steel

  • Thermowell / protection tube

    welded protection tube or to be used with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    Thermowell:

    9x1,25 mm

    11x2 mm

    12x2,5 mm

    14x2 mm

    16x3,5

    1/4" SCH80

    1/2" SCH80

    1/2" SCH40

  • Max. immersion length on request

    up to 4.500,0 mm (177'')

  • Material protection tube/ thermowell

    316 (1.4401)

    316L (1.4404)

    316Ti (1.4571)

    Alloy 600 (2.4816)

    Alloy C276 (2.4819)

    Alloy 446 (1.4749)

    Alloy 321 (1.4541)

    Sheath PTFE

    Sheath Tantal

  • Process connection

    Thread:

    G3/8, G1/2", G3/4", G1"

    NPT1/2", NPT3/4", NPT 1"

    M18x1.5, M20x1.5, M27x2, M33x2

    R1/2", R3/4"

    Cap-nut:

    M20x1.5, G1/2", G3/4"

    Compression fitting:

    NPT1/2", G1/2", G1"

    Flansche:

    DN15 PN40 B1, C

    DN25 PN20, PN40, PN100 B1, B2, C

    DN40 PN40 B1

    DN50 PN40 B1

    ASME 1" 150 RF

    ASME 1" 300 RF

    ASME 1 1/2" 150 RF

    ASME 2" 150 RF

    ASME 2" 300 RF

  • Tip shape

    straight

    reduced

    tapered

    optimized for quick response times

  • Surface roughness Ra

    < 1.6 μm (63.00 μin)

  • Operating temperature range

    PT100 TF StrongSens:

    -50 °C ...500 °C

    (-58 °F ...932 °F)

    PT100 QuickSensTF:

    -50 °C …200 °C

    (-58 °F …392 °F)

    PT100 WW:

    -200 °C ...600 °C

    (-328 °F ...1.112 °F)

    PT100 TF:

    -50 °C ...400 °C

    (-58 °F ...752 °F)

    Thermoelement:

    Typ K up to 1.100 °C (2.012 °F)

    Typ J up to 800 °C (1.472 °F)

    Typ N up to 1.100 °C (2.012 °F)

  • Max. process pressure (static)

    depending on the configuration up to 100 bar

  • Accuracy

    Class AA acc. to IEC 60751

    Class A acc. to IEC 60751

    Class B acc. to IEC 60751

    Class special or standard acc. to ASTM E230

    Class 1 or 2 acc. to IEC 60584-2

  • Response time

    fastest response time with thermowell t90 starting at below 10 s

    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX

    ATEX IECEx

    NEPSI

    IECEx

    EAC Ex

    CSA C/US

  • Certification

    SIL, MID, DNV/GL

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • C
    • Order code 71367406

      Spare parts kit copper ring G3/8",(10 p)

      Packing unit: 10 pieces

    • Order code 71367414

      Spare parts kit copper ring G1/2",(10 p)

      Packing unit: 10 pieces

    • Order code 71367420

      Spare parts kit copper ring G3/4",(10 p)

      Packing unit: 10 pieces

    • Order code 71367424

      Spare parts kit copper ring G1",(10 p)

      Packing unit: 10 pieces

    • Order code 71367425

      Spare parts kit copper ring M20x1.5(10p)

      Packing unit: 10 pieces

    • Order code 71111513

      Term.block DIN B (42mm) 3 term. 5 pc

    • Order code 71111514

      Term.block DIN B (42mm) 4 term. 5 pc

    • Order code 71111515

      Term.block DIN B (42mm) 6 term. 5 pc

    • Order code 71249291

      Thermo-conductive paste FDA-conform 30g

    • Order code 71312729

      Thermoconductive Paste HSC 340, 100g

    • Order code TK40-

      iTHERM TK40 Compression Fitting

      Weld-in compression fitting with hygienic design. For applications in the food/ beverages and pharmaceutical industries.

    • Order code XPT0001-

      Spare Part Kit Sealing for TK40 XPT0001

      delivery: 5 parts per kit

    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

    • Order code 71090687

      Fieldbus connector PA M20;M12; L150

    • Order code XPT0004-

      Spare parts kit cover terminal headTA30R

      cover of connecting head

    • Order code TA20AB-

      Terminal Head TA20AB

      Terminal head for temperature assemblies, simple execution, lid fixed by screws. Inner geometry acc. to DIN EN 50446.

    • Order code TA30A-

      Terminal Head TA30A

      Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Order code TA30D-

      Terminal Head TA30D

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Order code TA30EB-

      Terminal Head TA30EB

      Retainer for terminal block or head transmitter + optional display. Cover: low, threaded, optional window. Material: Aluminium. Coating: Polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...+150oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Order code TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

    • Order code TA30P-

      Terminal Head TA30P

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).

    • Order code TA30R-

      Terminal Head TA30R

      Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.

    • Order code 71158816

      O-Ring 88x3 EPDM70 PTFE-coated

    • Order code TE131-

      Extension Neck TE131

    • Order code TT131-

      Thermowell TT131

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT71-

      iTEMP TMT71, Transmitter 4-20mA

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Order code TMT72-

      iTEMP TMT72, Transmitter HART

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT162-

      iTEMP TMT162, Field Transmitter

      Temperature transmitter. Application: RTD, TC, Ohm, mV. HART, PROFIBUS PA Profile 3.02 or FOUNDATION Fieldbus separately available. Galvanic isolation 2 kV (sensor input/output). NEMA Type 4X Encl., IP67. Dual compartment. DNV GL marine approval (only HART). UL listed.

    • Order code TS111-

      Insert iTHERM TS111

      Replaceable. Metric version according DIN43735.

    • Order code TS211-

      Insert iTHERM TS211

    • Order code TM131-

      Thermometer TM131

      Modular thermometer with resistance sensor or thermocouple. Metrical version with exchangeable insert for demanding applications in the chemical, oil/gas and power industry. With thermowell or to be installed into thermowell. Measuring range: -200...+1.100oC/ -328...2.012oF (depending on the configuration). ::Fastest response times for optimal process control through iTHERM QuickSens insert and fast response thermowell options. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. ::Cost savings with recalibrations through iTHERM QuickNeck coupling ::Material selection for a wide range of applications.