Specs at a glance
-
Measurement range
0 to 14 pH
-
Process temperature
0 to 110 °C (32 to 230 °F)
-
Process pressure
1 to 14 bar (15 to 203 psi)
Field of application
Orbipore CPS91D is the digital specialist for fibrous media or media with a high content of suspended solids such as dispersions, precipitation reactions or emulsions. The open aperture prevents fouling and guarantees you the most reliable measurement under extreme process conditions. Orbipore CPS91D is not the latest Memosens generation. To get information on the new Memosens CPS91E sensor with extended functionality, click here.
Chemical processes
Pulp and paper industry
Contaminated media and suspended solids
- Dispersions
- Precipitation
- Emulsions
With ATEX, FM, and CSA approval for application in hazardous areas.
Benefits
Open aperture for application in heavily soiled media
Low maintenance and long service life due to stabilized gel filling
Not affected by fluctuations in pressure and temperature
Maximum process safety through non-contact inductive signal transmission
Enables predictive maintenance due to storage of sensor and process-specific data
Reduced operating costs thanks to minimized process downtime and extended sensor lifetime
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Orbipore CPS91D and CPS91 Technical Information
pH electrodes, analog orwith digital Memosens technology
EN 31/10/201501/02/200801/03/2004Language:
English
Version:
31/10/2015
File size:
415.7 KB
File name:
TI00375CEN_1415.pdf
-
-
-
Operating Instruction (BA)
pH/ORP sensors and reference half cells
Sensors with Memosens technology and analog sensors
EN 04/05/202031/12/201730/11/2015Language:
English
Version:
04/05/2020
File size:
1.1 MB
File name:
BA01572CEN_0320.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous
areasEN 11/11/201631/12/201101/04/2009Language:
English
Version:
11/11/2016
File size:
3.7 MB
File name:
XA00079CA3_1416.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous
areasEN 22/02/201604/03/201514/01/201321/10/201001/12/2006Language:
English
Version:
22/02/2016
File size:
4.3 MB
File name:
XA00376CA3_1616.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to: BA01572C, BA01109C
Safety instructions for electrical equipment in explosion-hazardous
areas
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
EAC Ex 0Ex iaIIC T4/T6 Ga XEN 01/03/202218/02/202108/03/2016Language:
English
Version:
01/03/2022
File size:
508.1 KB
File name:
XA01437CEN_0322-00.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens ph/ORP sensors
pH/ORP measurement
Supplement to BA01572C, BA01109C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UKEx II 1 G Ex ia IIC T3/T4/T6 Ga
UK Ex II 1 G Ex ia IIC T4/T6 GaLanguage:
English
Version:
08/12/2021
File size:
435.2 KB
File name:
XA02786CEN_0121-00.pdf
-
-
-
Special Documentation (SD)
Kurzanleitung pH-/Redox-Sensoren - Short Instructions pH/ORP sensors
pH-/Redox-Sensoren - pH/ORP sensors
EN 01/04/200701/09/1999Language:
English
Version:
01/04/2007
File size:
361.7 KB
File name:
SD050Ca2.pdf
-
-
-
Special Documentation (SD)
Memoclip
Äußere Kennzeichnung von digitalen Sensoren und Kabeln mit
Memosens-TechnologieEN 01/03/2007Language:
English
Version:
01/03/2007
File size:
284.4 KB
File name:
SD124Ca2.pdf
-
-
-
Fields of Activities (FA)
Catálogo Portfolio Analítica
Desde sensores hasta soluciones completas
Language:
Spanish
Version:
12/01/2017
File size:
1.5 MB
File name:
FA01018CES_Portfolio_Analitica_0216.pdf
-
-
-
Fields of Activities (FA)
Jistota v analýze kapalin
Od senzorů po kompletní dodávku na klíč
Language:
Czech
Version:
12/01/2017
File size:
740.3 KB
File name:
Analyza_FA01018Ccs_0216.pdf
-
-
-
Fields of Activities (FA)
Esperti nell’analisi dei liquidi
Dai sensori singoli a soluzioni
complete “chiavi in mano”Language:
Italian
Version:
12/01/2017
File size:
3.9 MB
File name:
FA01018CIT_02.16.pdf
-
-
-
Case Study (CS)
Process automation worth its weight in gold
Memosens pH sensors improve processes at Agnico Eagle
Language:
English
Version:
01/07/2016
File size:
1.5 MB
File name:
CS01496CEN_0116_Agnico Eagle goldmine.pdf
-
-
-
Case Study (CS)
Prozessautomatisierung, die Gold wert ist
Memosens pH-Sensoren verbessernProzesse bei Agnico Eagle
Language:
German
Version:
01/07/2016
File size:
1.5 MB
File name:
CS01496CDE_0116_Agnico Eagle Goldmine.pdf
-
-
-
Case Study (CS)
L’automatisation des process vaut son pesant d’or
Memosens Les sondes de pH améliorent les process chez Agnico Eagle
Language:
French
Version:
01/07/2016
File size:
673.1 KB
File name:
CS01496CFR-0216-Agnico Eagle.pdf
-
-
-
White paper (WP)
Damit bei der pH-Messung höchste Genauigkeit garantiert ist
Kalibrierung,Justierung und Verifizierung
Language:
German
Version:
07/04/2021
File size:
605.2 KB
File name:
WP01154C07DE_01.21_Damit bei der pH-Messung hoechste Genauigkeit garantiert ist.pdf
-
-
-
White paper (WP)
Ensuring maximum accuracy in pH measurement
Calibration, adjustment and verification
Language:
English
Version:
07/04/2021
File size:
600 KB
File name:
WP01154C07EN_01.21_Ensuring maximum accuracy in pH measurement.pdf
-
-
-
Manufacturer Declaration
Product family: CeraGel, CeraLiquid, Memosens, OrbiPore, OrbiSint
Product root: CPS11-, CPS11D-, CPS12D-, CPS31D-, CPS41-, CPS41D-,
CPS71D-, CPS72D-, CPS91D-
Declaration number: HE_01182_01.19
Manufacturer specification: RoHSLanguage:
Chinese
Version:
18/09/2019
File size:
425.1 KB
File name:
HE_01182_01.19.pdf
-
-
-
Manufacturer Declaration
Product family: Memosens, OrbiPore, OrbiSint
Product root: CPF81E-, CPF82E-, CPS11D-, CPS11E-, CPS12D-, CPS12E-, CPS16E-, CPS31D-, CPS31E-, CPS41E-, CPS42E-, CPS47E-, CPS61E-, C
PS71E-, CPS72E-, CPS76E-, CPS77E-, CPS91D-, CPS91E-, CPS92D-, CPS92E-, CPS96E-, CPS97E-
Declaration number: HE_01379_03.23
Manufacturer specification: PED
Additional information: CRNEN 10/05/2023Language:
English
Version:
10/05/2023
File size:
306.9 KB
File name:
CPSxxE_CRN_HE_01379_03.23.pdf
-
-
-
EU Declaration
Product family: CeraGel, CeraLiquid, Memosens, OrbiPore, OrbiSint
Product root: CPS11D-, CPS12D-, CPS16D-, CPS41D-, CPS42D-,
CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CPS96D-
Declaration number: EC_00385_02.16EN 22/07/2017Language:
English
Version:
22/07/2017
File size:
556.7 KB
File name:
EC_00385_02.16.pdf
-
-
-
EU Declaration
Product family: CeraGel, CeraLiquid, Ceramax, ConduMax H, ConduMax W, InduMax H, InduMax P, Liquiline, Memosens, Messkabel, Orbi Pac, OrbiPore, OrbiSint, OxyMax H, OxyMax W, TopHit
Product root: CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS54D-, CLS82D-,
CML18-, COS21D-, COS22D-, COS51D-, COS81D-, CPF82D-, CPL51E-
,
CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-,
CPS42D-, CPS441D-, CPS471D-, CPS47D-, CPS491D-, CPS71D-,
CPS72D-,
CPS77D-, CPS91D-, CPS92D-, CPS96D-, CPS97D-, CYK10-, CYK20-
Declaration number: EC_00828_02.20EN 14/02/2022Language:
English
Version:
14/02/2022
File size:
281.9 KB
File name:
EC_00828_03.22_D-Sensoren CML18 EMV_RoHS.pdf
-